AIR COOLED AFTER COOLER - ACC SERIES
SALIENT FEATURES
- Work pressure - 16 bar
- Heat exchanger is fully enclosed.
- Compact Size.
- Low power consumption
- Easy for installation
- Corrosion resistance painting
- High Efficiency copper tubes.
- Optional Vortex Separator for 99.99% moisture removal.
- Continuous duty motor with Aluminium / highly reliable plastic fans.
- Most suitable for portable applications.
Dryers are sized according to the flow, pressure, temperature and dew point required of the compressed air. If these conditions are changed, the resulting efficiency of the dryer can be drastically affected. The temperature of the compressed air leaving a compressor varies from 82 °C to 177 °C, depending on the type of compressor, it is essential that an After Cooler be installed upstream of most dryers because it will lower the temperature to required level and will remove 50 to 75% of water vapour contained in the air. After coolers are available in either air or water cooled units.
Air Cooled After Cooler
Air cooled After Coolers are of fine-tube construction with the compressed air passing through the tube. Air Cooled After Cooler transfer the heat from the compressed air to the atmosphere. The compressed air is cooled using a cooler fan. Air Cooled After Coolers are preferred because it is easy to install and no additional pipe lines for water and easy to maintain.
TECHNICAL SPECIFICATIONS
Model | Capacity |
Working Pressure |
Power Req. |
Electrical Conn. |
In/Out Conn. |
Dimension mm |
Weight | ||||
CFM | m³/hr | bar | Kw |
220V 1PH 50 HZ |
415V 3PH 50Hz |
BSP | A | B | C | Kg. | |
ACC003 | 35 | 58 | 16 | 0.036 | 1/2" | 422 | 120 | 727 | 45 | ||
ACC005 | 50 | 83 | 16 | 0.11 | 3/4" | 513 | 140 | 806 | 50 | ||
ACC010 | 100 | 170 | 16 | 0.24 | 1 1/2" | 622 | 160 | 905 | 75 | ||
ACC015 | 150 | 255 | 16 | 0.24 | 1 1/2" | 622 | 160 | 905 | 75 | ||
ACC020 | 200 | 340 | 16 | 0.24 | 2" NB FLG | 900 | 230 | 1080 | 140 | ||
ACC030 | 300 | 510 | 16 | 0.24 | 2" NB FLG | 900 | 230 | 1080 | 150 | ||
ACC040 | 400 | 680 | 16 | 0.55 | 2" NB FLG | 920 | 920 | 1285 | 200 | ||
ACC060 | 600 | 1020 | 16 | 0.75 | 3" NB FLG | 1000 | 1080 | 1055 | 220 | ||
ACC075 | 750 | 1275 | 16 | 1.5 | 3" NB FLG | 1750 | 1524 | 1500 | 250 | ||
ACC100 | 1000 | 1700 | 16 | 1.5 | 4" NB FLG | 1750 | 1524 | 1500 | 250 |
Air inlet temperature is 90ºC, Air outlet temperature is 45ºC
* Product Design and specifications are subject to change due to constant upgradation.
Download brochure of AIR COOLED AFTER COOLER - ACC SERIES